R Value was calculated for the
Tempshield® Reflective (Bubble) Post Frame Insulation by using the following assembly: corrugated metal exterior, 2" x 4" purlins, Tempshield® Reflective (Bubble) Post Frame Insulation, a 2" x 6" to represent the top cord of a truss, and 1/2" wafer board. The thermal values are for both exposed insulation and applications where the insulation is covered for fire codes.
Thermal Values |
Heat Flow Up |
Heat Flow Down |
U Value Up |
U Value Down |
K Value Up |
K Value Down |
TempShield® w/Wafer Board |
6.93 |
15.11 |
.144 |
.066 |
.144 |
.066 |
TempShield® w/Metal Interior |
6.22 |
14.40 |
.161 |
.069 |
.161 |
.069 |
TempShield® Exposed to Interior |
4.91* |
12.81* |
.204* |
.078* |
.204* |
.078* |
All Thermal Values are corrected for frame loss.
* Includes thermal resistance of 1.32 UP and 4.55 DOWN for interior air film.
WALLS
The thermal values for TempShield® installed in the walls of post frame buildings are based on testing of an assembly consisting of corrugated metal exterior, 2" x 4" girts, TempShield® Insulation, a 4" x 6" to represent the support beam, and 1/2" wafer board as an interior wall covering.
Thermal Values |
Heat Flow Horiz. |
U Value Horiz. |
K Value Horiz. |
TempShield® w/Wafer Board |
6.93 |
.144 |
.144 |
TempShield® w/Metal Interior |
6.22 |
.161 |
.161 |
TempShield® Exposed to Interior |
4.91* |
.204* |
.204* |
All Thermal Values are corrected for frame loss.
* Includes thermal resistance of 1.70 for interior air film.