Radiant Barrier

Metal Building Construction

METAL CEILING

To achieve R value in the ceiling, Tempshield® Reflective (Bubble) Insulation was tested using the following assembly: a corrugated metal exterior, 1/2″ extruded polystyrene thermal breaks 5′ on center, TempShield® Reflective (Bubble) Insulation, and 8″ Z purlins commonly used in metal buildings.

Thermal ValuesHeat Flow UpHeat Flow DownU Value UpU Value Down
TempShield® w/Wafer Board5.027.93.199.126
TempShield® w/Metal Interior4.297.29.233.137
TempShield® Exposed to Interior3.63*7.26*.275*.138*

All Thermal Values are corrected for frame loss.
* Includes thermal resistance of 1.32 UP and 4.55 DOWN for interior air film.

WALLS

To achieve R value in the walls, Tempshield® Reflective (Bubble) Insulation was tested using the following assembly: a corrugated metal exterior, 1/2″ extruded polystyrene thermal breaks, TempShield® Reflective (Bubble) Insulation, 8″ Z purlins, and 1/2″ wafer board to represent an interior finished wall.

Thermal ValuesHeat Flow Horiz.U Value Horiz.
TempShield® w/Wafter Board5.45.183
TempShield® w/Metal Interior4.77.210
TempShield® Exposed to Interior4.50*.222*

*Includes thermal resistance of 1.70 for interior air film.