Radiant Barrier

Tempshield® Reflective (Bubble) Post Frame Insulation

R Value was calculated for the Tempshield® Reflective (Bubble) Post Frame Insulation by using the following assembly: corrugated metal exterior, 2″ x 4″ purlins, Tempshield® Reflective (Bubble) Post Frame Insulation, a 2″ x 6″ to represent the top cord of a truss, and 1/2″ wafer board. The thermal values are for both exposed insulation and applications where the insulation is covered for fire codes.

Thermal ValuesHeat Flow UpHeat Flow DownU Value UpU Value DownK Value UpK Value Down
TempShield® w/Wafer Board6.9315.11.144.066.144.066
TempShield® w/Metal Interior6.2214.40.161.069.161.069
TempShield® Exposed to Interior4.91*12.81*.204*.078*.204*.078*

All Thermal Values are corrected for frame loss.
* Includes thermal resistance of 1.32 UP and 4.55 DOWN for interior air film.

WALLS

The thermal values for TempShield® installed in the walls of post frame buildings are based on testing of an assembly consisting of corrugated metal exterior, 2″ x 4″ girts, TempShield® Insulation, a 4″ x 6″ to represent the support beam, and 1/2″ wafer board as an interior wall covering.

Thermal ValuesHeat Flow Horiz.U Value Horiz.K Value Horiz.
TempShield® w/Wafer Board6.93.144.144
TempShield® w/Metal Interior6.22.161.161
TempShield® Exposed to Interior4.91*.204*.204*

All Thermal Values are corrected for frame loss.
* Includes thermal resistance of 1.70 for interior air film.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare
Need Help? Call Now